Air conditioning. Heating. Everything in between.Talk to a specialist · (818) 785-4151
GenieFind a Contractor
Back to equipment
GA23-12CRN1-230 product series

Accessories

GA23-12CRN1-230

$787.00

Source-listed pricing. Call to confirm current price, availability, specifications, and installation requirements before ordering.

Capacity
12,000 BTU
Voltage
230 V
Call about this modelEmail an inquiry

Product images may show a representative series. Confirm the exact configuration with our team.

View specifications

TECHNICAL DETAILS

GA23-12CRN1-230 specifications

GA23-12CRN1-230 Specs

SpecificationValue
BrandGENIEAIRE
System TypeCooling Only
Power Supply208And230V_1Ph,FREQUENCY_60HZ
Cooling Capacity (Btu/hr)12000/11700
Cooling EER (W/W)Infinity
Cooling CEER (Btu/h/W)9.5
Cooling Input (W)1180/1160
Cooling Current (A)6.5/7.0
Cooling Standby Power (W)1.458
Heating Capacity PTC (Btu/hr)10600/8600
Heating Input (W)3450/2821
Heating Current (A)15/13.5
Moisture Removal (L/h)1.2
Rated Power Input (W)3450
Rated Current (A)15
Starting Current (A)45
Compressor ModelKSM100N11VEZ
Compressor TypeROTARY
Compressor BrandGMCC
Compressor Capacity (W)3590/3620
Compressor Input (W)850/875±3%
Compressor Current (A)4.18/3.85±3%
Compressor Locked Rotor Amp LRA (A)28.5±10%
Thermal ProtectorUP-A2H/HPA-325H
Thermal Protector PositionINTERNAL
Capacitor35 uF
Refrigerant Oil TypeVG68
Refrigerant Oil Charge (ml)300±15
Refrigerant TypeR32
Refrigerant Charge (kg)0.49
Refrigerant Charge (oz)17.28
Design Pressure High (psi)300
Design Pressure Low (psi)520
Fan Motor ModelZKFP-120-8-97L
Fan Motor Input (W)130
Fan Motor Current (A)1.15
Fan Motor Speed Hi (r/min)1550
Fan Motor Speed Mi (r/min)1440
Fan Motor Speed Lo (r/min)1340
Fan Motor Insulation ClassB
Fan Motor Waterproofing ClassIP24
Evaporator Number of Rows3
Evaporator Tube Pitch (a) x Row Pitch (b) (mm)19.5x11.6
Evaporator Fin Spacing (mm)1.3
Evaporator Fin TypeHydrophilic aluminum
Evaporator Tube Outside Dia and Type (mm)Φ7 Inner groove tube
Evaporator Coil Length x Height x Width (mm)505x252x53.48
Evaporator Number of Circuits4
Evaporator Indoor Side Air Flow Hi (m3/h)465
Evaporator Indoor Side Air Flow Mi (m3/h)428
Evaporator Indoor Side Air Flow Lo (m3/h)392
Evaporator Indoor Side Air Flow Hi (ft³/min)273.53
Evaporator Indoor Side Air Flow Mi (ft³/min)251.76
Evaporator Indoor Side Air Flow Lo (ft³/min)230.59
Evaporator Indoor Side Noise Level Hi dB(A)61.8
Evaporator Indoor Side Noise Level Mi dB(A)60
Evaporator Indoor Side Noise Level Lo dB(A)58
Condenser Number of Rows3
Condenser Tube Pitch (a) x Row Pitch (b) (mm)19.5x11.6
Condenser Fin Spacing (mm)1.2
Condenser Fin TypeHydrophilic aluminum
Condenser Tube Outside Dia and Type (mm)Φ5 Inner groove tube
Condenser Coil Length x Height x Width (mm)380x351x34.8
Condenser Number of Circuits2
Condenser Outdoor Air Flow Hi (m3/h)767
Condenser Outdoor Air Flow Med (m3/h)695
Condenser Outdoor Air Flow Lo (m3/h)623
Condenser Outdoor Air Flow Hi (ft³/min)451.18
Condenser Outdoor Air Flow Med (ft³/min)408.82
Condenser Outdoor Air Flow Lo (ft³/min)366.47
Condenser Outdoor Side Noise Level Hi dB(A)65.4
Condenser Outdoor Side Noise Level Med dB(A)63.2
Condenser Outdoor Side Noise Level Lo dB(A)61.1
Plug TypeLCDI(6-20P)
Power Cord Type12#x3
Power Cord Length (mm)1700
Power Cord Length (ft)5.58
Control TypeRemote Control
Indoor Operating Temp Cooling Min (°C)17
Indoor Operating Temp Cooling Max (°C)32
Indoor Operating Temp Cooling Min (°F)62
Indoor Operating Temp Cooling Max (°F)90
Outdoor Operating Temp Cooling Min (°C)18
Outdoor Operating Temp Cooling Max (°C)43
Outdoor Operating Temp Heating Min (°C)-5
Outdoor Operating Temp Heating Max (°C)24
Outdoor Operating Temp Cooling Min (°F)64
Outdoor Operating Temp Cooling Max (°F)109
Outdoor Operating Temp Heating Min (°F)5
Outdoor Operating Temp Heating Max (°F)75
Dimension Width (mm)615
Dimension Depth (mm)515
Dimension Height (mm)369
Dimension Width (in)24.21
Dimension Depth (in)20.28
Dimension Height (in)14.53
Packing Width (mm)710
Packing Depth (mm)675
Packing Height (mm)430
Packing Width (in)27.95
Packing Depth (in)26.57
Packing Height (in)16.93
Net Weight (kg)34
Gross Weight (kg)38.9
Net Weight (lb)74.96
Gross Weight (lb)85.76
Loading Quantity 20ft (pieces)120
Loading Quantity 40ft (pieces)255
Loading Quantity 40HQ (pieces)306
Window Opening Width Min (in)26.8
Window Opening Width Max (in)36
Window Opening Height Min (in)15.5
ModelGA23-12CRN1-230

YOUR LOCAL HVAC CONNECTION

Come talk comfort.

Genie Air Conditioning and Heating, Inc.
15041 Calvert St.
Van Nuys, CA 91411

Get directions
(818) 785-4151

[email protected]

Hours of operation

Monday–Friday
7:30 AM – 5:00 PM
Saturday
8:00 AM – 2:00 PM
Pacific Time

GUIDED EQUIPMENT ASSISTANT

Ask Genie

1. Your installation
Heat pump or heat strip?

A heat pump transfers heat; a heat strip uses electric resistance heating. The right choice depends on the unit, climate, and available electrical supply.

2. Space & measurements

If there is an existing sleeve, measure its outside dimensions in inches to the nearest ⅛ inch. Leave unknown measurements blank.

3. Power & quantity

Use known circuit information or ask a qualified electrician. Do not open electrical equipment to check.

4. How can we reach you?

Opens your email app with the details addressed to [email protected]. Review and send there. Nothing is submitted automatically.